{"id":654,"date":"2017-03-14T15:27:30","date_gmt":"2017-03-14T15:27:30","guid":{"rendered":"https:\/\/ventus.global\/blog\/?p=654"},"modified":"2017-03-28T18:24:39","modified_gmt":"2017-03-28T18:24:39","slug":"nueva-norma-de-medicion-de-curva-de-potencia-beneficios-y-oportunidades","status":"publish","type":"post","link":"https:\/\/ventus.global\/blog\/nueva-norma-de-medicion-de-curva-de-potencia-beneficios-y-oportunidades\/","title":{"rendered":"NUEVA NORMA DE MEDICI\u00d3N DE CURVA DE POTENCIA: BENEFICIOS Y OPORTUNIDADES"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-544\" src=\"https:\/\/ventusenergia.com\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS.jpg\" alt=\"SIEMENS BRASIL WINDCBRE VENTUS\" width=\"960\" height=\"1050\" srcset=\"https:\/\/ventus.global\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS.jpg 960w, https:\/\/ventus.global\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS-274x300.jpg 274w, https:\/\/ventus.global\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS-768x840.jpg 768w, https:\/\/ventus.global\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS-936x1024.jpg 936w, https:\/\/ventus.global\/blog\/wp-content\/uploads\/2017\/01\/SIEMENS-BRASIL-WINDCBRE-VENTUS-400x438.jpg 400w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/p>\n<p style=\"text-align: justify;\">[tp lang=\u00bbes\u00bb not_in=\u00bben\u00bb]<br \/>\nEn los primeros d\u00edas del mes de marzo, la IEC (International Electrotechnical Commission), comisi\u00f3n referente a nivel global en la fijaci\u00f3n de normas electrot\u00e9cnicas, promulg\u00f3 la nueva edici\u00f3n de la norma IEC 61400-12-1:2017, acerca del procedimiento de calibraci\u00f3n del sitio medici\u00f3n de la curva de potencia de un aerogenerador.<\/p>\n<p style=\"text-align: justify;\">Esta nueva edici\u00f3n, que reemplaza a la primera versi\u00f3n redactada en 2005, establece actualizaciones y ajustes que brindan mayor precisi\u00f3n en la medici\u00f3n mediante el uso de nuevos procedimientos y tecnolog\u00edas, que pocas empresas en Am\u00e9rica Latina est\u00e1n preparadas para ofrecer. Adem\u00e1s, permitir\u00e1 economizar sensiblemente el proceso de medici\u00f3n de la curva de potencia.<\/p>\n<p style=\"text-align: justify;\">A continuaci\u00f3n, se listan algunos de los cambios m\u00e1s importantes de la nueva norma:<\/p>\n<ul style=\"text-align: justify;\">\n<ul>\n<li><strong>Inclusi\u00f3n de la metodolog\u00eda LiDAR y SODAR para la medici\u00f3n de la curva de potencia.<\/strong><br \/>\nLa norma de 2005 \u00fanicamente establec\u00eda que la medici\u00f3n se pod\u00eda realizar a trav\u00e9s de la colocaci\u00f3n de m\u00e1stiles meteorol\u00f3gicos.A partir de ahora, se tiene la posibilidad de utilizar las tecnolog\u00edas LiDAR y SODAR as\u00ed evitar, en la mayor\u00eda de los casos, el alquiler de m\u00e1stiles, permisos de construcci\u00f3n y permisos aeron\u00e1uticos, realizaci\u00f3n de fundaciones, etc. Esto posibilita que la campa\u00f1a sea m\u00e1s econ\u00f3mica y eficiente. Del mismo modo, los sensores remotos LiDAR permiten realizar mediciones a lo largo del rotor y as\u00ed, seg\u00fan la norma actualizada, reducir la incertidumbre del resultado y consecuentemente que los inversionistas tengan m\u00e1s certeza de sus ingresos a lo largo de la vida \u00fatil del proyecto.<\/p>\n<p><strong>La nueva inclusi\u00f3n de las tecnolog\u00edas LiDAR y SODAR son clave para economizar las campa\u00f1as de medici\u00f3n, ya que no requiere de una planificaci\u00f3n log\u00edstica minuciosa.<\/strong><\/p>\n<p>VENTUS cuenta con m\u00e1s de 2 a\u00f1os de experiencia trabajando con LiDARs, tanto de eje vertical como de eje horizontal. Como parte de nuestras investigaciones, hemos constatado que este cambio puede reducir la inversi\u00f3n en campa\u00f1as de medici\u00f3n de la curva de potencia hasta un 40% mediante el uso de esta tecnolog\u00eda.<\/p>\n<p>Adem\u00e1s de obtener claros beneficios econ\u00f3micos, esta tecnolog\u00eda arroja datos con mayor<br \/>\nprecisi\u00f3n e instantaneidad. Si a esto le sumamos que no es necesario la compra de un equipo LiDAR, ya que existen empresas como Ventus que alquilan para los mercados Latinoamericanos, se convierte en un m\u00e9todo considerablemente m\u00e1s eficiente y con mejores resultados para su campa\u00f1a de medici\u00f3n.<\/li>\n<li><strong>Ajuste de curva de potencia a partir del reconocimiento de turbulencia en el viento.<\/strong><br \/>\nLa turbulencia influye de una manera sumamente importante en el desempe\u00f1o del aerogenerador. En los \u00faltimos 5 a\u00f1os fue elaborada una metodolog\u00eda para cuantificar y medir este efecto. En nueva norma se incluye la metodolog\u00eda de correcci\u00f3n de la curva de potencia por turbulencia que permite reducir las incertidumbres del resultado y, en caso de ser necesario, aplicar los procedimientos acordados en el contrato con m\u00e1s certeza.<\/li>\n<\/ul>\n<\/ul>\n<p style=\"text-align: justify;\">\n<ul style=\"text-align: justify;\">\n<ul>\n<li><strong>Introducci\u00f3n del concepto de \u201cRotor Equivalent Wind Speed\u201d o \u201cVelocidad del barrido del rotor equivalente\u201d.<\/strong><br \/>\nAdicionalmente a medir la velocidad del viento en la altura del buje del aerogenerador, la nueva norma agrega la posibilidad de realizar mediciones a lo largo de rotor y asimismo reducir las incertidumbres de la curva medida.<br \/>\nLa velocidad del viento var\u00eda sensiblemente entre el punto m\u00e1s bajo por donde pasa la pala y el punto m\u00e1s alto. En los aerogeneradores disponibles en el mercado al d\u00eda de hoy puede haber una variaci\u00f3n de hasta 136 metros. Este nuevo procedimiento permite considerar este gradiente de viento, y as\u00ed medir la curva de potencia con m\u00e1s certeza.<\/li>\n<\/ul>\n<\/ul>\n<p style=\"text-align: justify;\">\n<ul style=\"text-align: justify;\">\n<li><strong>En caso de la utilizaci\u00f3n de las torres de medici\u00f3n, se establecen requerimientos m\u00e1s estrictos de los brazos de soporte de los anem\u00f3metros y la distancia de estos y la torre meteorol\u00f3gica.<\/strong> De este modo se reduce la incertidumbre en la medici\u00f3n.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Por m\u00e1s informaci\u00f3n acerca de la nueva norma IEC 61400-12-1:2017, consultas sobre campa\u00f1as de medici\u00f3n o verificaci\u00f3n de curva de potencia, o alquiler de equipos LiDAR, favor contactarse con <a href=\"https:\/\/ventusenergia.com\/contacto.php\" target=\"_blank\">nuestras oficinas en Am\u00e9rica Latina.<\/a><br \/>\n[\/tp]<\/p>\n<p style=\"text-align: justify;\">[tp lang=\u00bben\u00bb not_in=\u00bbes\u00bb]<br \/>\nAt the beginning of March, the International Electrotechnical Commission (IEC), worldwide reference for electrotechnical standards, issued a new version of IEC standard 61400-12-1:2017 regarding the calibration procedure for the measurement location of a wind turbine power curve.<\/p>\n<p style=\"text-align: justify;\">The new version to replace the initial 2005 document determines updates and adjustments that result in higher precision measurements with the support of new procedures and technologies that only a few companies in Latin America are ready to handle. Additionally, it leads to a considerable reduction in the costs of the power curve measurement process.<\/p>\n<p style=\"text-align: justify;\">Some of the most important changes of the new standard are listed below:<\/p>\n<ul style=\"text-align: justify;\">\n<ul>\n<li><strong>Inclusion of the SODAR and LiDAR methodology for power curve measurements.<\/strong><br \/>\nThe 2005 standard merely determined that measurement could be made using met masts.From now on, it will be possible to use LIDAR and SODAR remote sensing technologies to avoid, in most cases, the need to rent met masts, construction permits, aeronautical permits, foundation construction, etc. In consequence, campaigns become more economical and efficient. Similarly, LiDAR remote sensors make it possible to obtain measurements along the rotor, and according to the terms of the updated version, this reduces the uncertainty of results so that investors can be more certain about the income they are getting throughout the useful life of the project.<\/p>\n<p><strong>The inclusion of LiDAR and SODAR technologies is crucial to limit the costs of measurement campaigns as detailed logistics planning is no longer required.<\/strong><\/p>\n<p>VENTUS has been working with LiDAR, both along the vertical and longitudinal axis, for the past two years. As part of our research, we have found that the use of this technology may reduce investment of power curve measurement campaigns by up to 40%.<\/p>\n<p>There are also significant economic benefits as this technology provides more precise and immediate data. If we also consider that it is not necessary to buy a LiDAR unit because there are companies such as Ventus that rent them for the Latin American market, it becomes a considerable more efficient method with better results for your measurement campaign.<\/li>\n<li><strong>Power curve adjustment with wind turbulence is considered.<\/strong><br \/>\nTurbulence affects the performance of wind turbines in a very significant manner. During the past 5 years, a new method was developed to quantify and measure this effect. The new standard includes a correction methodology for the turbulence in the power curve. This leads to less uncertainty regarding the outcome and, if necessary, the procedures agreed upon in the contract can be applied with more certainty.<\/li>\n<\/ul>\n<\/ul>\n<p style=\"text-align: justify;\">\n<ul style=\"text-align: justify;\">\n<ul>\n<li><strong>Introduction of the \u201cRotor Equivalent Wind Speed\u201d concept.<\/strong><br \/>\nThe new standard does not only measure wind speed at the hub of the wind turbine but it also considers the possibility of measuring along the rotor reducing the uncertainty of the measured curve.Wind speed varies significantly between the lowest and the highest point where the blade spins. Turbines available in the market today evidence up 136 m of variation. This new procedure contemplates this wind gradient so that the power curve can be measured more accurately.<\/li>\n<\/ul>\n<\/ul>\n<p style=\"text-align: justify;\">\n<ul style=\"text-align: justify;\">\n<li><strong>When measurement towers are being used, more strict requirements are set for the anemometer support arms and for the distance between them and the met tower.<\/strong> This reduces the uncertainty in the measurement.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">For more information about the new IEC standard 61400-12-1:2017, questions about measurement campaigns, verification of power curves or rental of LiDAR equipment, please contact<a href=\"https:\/\/ventusenergia.com\/contacto.php\" target=\"_blank\"> our offices in Latin America.<\/a><br \/>\n[\/tp]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[tp lang=\u00bbes\u00bb not_in=\u00bben\u00bb] En los primeros d\u00edas del mes de marzo, la IEC (International Electrotechnical Commission), comisi\u00f3n referente a nivel global en la fijaci\u00f3n de normas electrot\u00e9cnicas, promulg\u00f3 la nueva edici\u00f3n de la norma IEC 61400-12-1:2017, acerca del procedimiento de calibraci\u00f3n del sitio medici\u00f3n de la curva de potencia de un aerogenerador. Esta nueva edici\u00f3n, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[41,31,40,17],"tags":[],"class_list":["post-654","post","type-post","status-publish","format-standard","hentry","category-argentina","category-recurso-eolico","category-uruguay","category-ventus"],"_links":{"self":[{"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/posts\/654","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/comments?post=654"}],"version-history":[{"count":7,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/posts\/654\/revisions"}],"predecessor-version":[{"id":697,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/posts\/654\/revisions\/697"}],"wp:attachment":[{"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/media?parent=654"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/categories?post=654"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ventus.global\/blog\/wp-json\/wp\/v2\/tags?post=654"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}